In living systems, complex nano- and microscale structures perform a
host of physical and biological functions. While two-dimensional
patterns can be recreated fairly well with techniques like
microlithography, three-dimensional structures represent a big
challenge. In the journal Angewandte Chemie, American researchers have
now reported a new method for the lithography-free etching of complex
surface motifs with the use of biodegradable polymers and enzymes.
Starting with structured microchannels, they have built an assembly for
the isolation and concentration of cells from whole blood.
A team led by Victor M. Ugaz at Texas A&M University uses proteinase K
(PK), a protein-cleaving enzyme that can also break down the bioplastic
polylactic acid. First, the researchers apply a mask to a small block of
polylactic acid, leaving only a narrow trail. The liquid containing PK
is directed through this microchannel. Wherever the enzyme comes into
contact with the polylactic acid, the latter is etched away.
Within microchannels, liquids can flow past each other without
appreciable mixing. The researchers use this phenomenon to make
structured channels. They direct PK solution through the channels on the
left and right, while allowing a protein solution flowing through the
middle to inhibit the etching process. This etches neighboring channels
separated by a “weir” into the polymer. In the next step, a protein
solution is directed through one of the etched channels and over the
central weir, while the second channel is further etched with PK. This
allows one channel to remain flat while the second is made deeper.
Finally, all three “tracks” are made even deeper with PK. This causes
the top of the weir to be lower than the outer edges of the double
channel.
To make their device, the researchers bent one such channel into a
hairpin turn and put a lid over it. They allow blood spiked with tumor
cells to flow through the inner, flatter channel. A buffer solution
flows through the deeper outer channel. In the curve, centrifugal forces
push blood cells into the outer track with the buffer. However, the
small space between the top of the weir and the lid over the system only
allows small blood cells to pass through. The larger tumor cells do not
fit through and become more concentrated in the inner channel as the red
blood cells become less concentrated. The different depths of the
channels enhances this process. Rare cells like freely circulating tumor
cells can be detected much more rapidly and easily when blood samples
are tested by this method than by conventional methods like membrane
filtration.
Special thermal preparation allows for the targeted formation of
crystalline regions in the polylactic acid. PK does not degrade these
regions well. This allows for the formation of defined small obstacles
within the channels, which could be useful in filtration or
chromatography systems.