Complex laboratory investigations do produce reliable results, but they
are not useful for point-of-care diagnostics. This is especially true in
developing countries, which must rely on simple, inexpensive test
methods that do not require a power source. Biosensors based on paper
are an interesting alternative. American researchers from the University
of Texas at Austin and the University of Illinois at Urbana-Champaign
have now introduced a particularly clever concept in the journal
Angewandte Chemie: print on one side of the paper, fold it up
origami-style, laminate it, and the test is ready. Test evaluation
requires only a voltmeter.
The team of researchers uses chromatography paper fabricated by wax
printing. The printed areas become hydrophobic, while the unprinted
paper remains hydrophilic. On one half of the paper, the researchers led
by Richard M. Crooks and Hong Liu created a sample inlet and two
hydrophilic channels, each leading from the inlet to a small chamber.
The two chambers are connected to each other through a narrow opening.
The required reagents are also “printed” onto the paper. On the second
half of the paper, a screen-printing process is used to add two
electrodes made of conductive carbon ink. When the paper is then folded
down the middle according to the principles of origami—no tape or glue—a
three-dimensional structure is formed. This causes the electrodes to
come into contact with the chambers. Finally, the folded paper is
laminated.
When a drop of the sample is put into the inlet, the liquid moves
through the two channels. One of the channels contains microspheres
coated with an aptamer. An aptamer is a strand of DNA that can be
constructed so as to selectively bind nearly any desired analyte
molecule. For the purpose of demonstration, the researchers chose an
aptamer for adenosine. If adenosine is in the sample, the aptamer binds
to it. This releases an enzyme that was coupled to the aptamer. The
enzyme continues to flow through the channel and reaches the chamber,
which contains glucose and Prussian blue (iron hexacyanoferrate). This
complex contains trivalent iron. The enzyme, glucose oxidase, oxidizes
the glucose, which causes the iron in the Prussian blue to be reduced to
the divalent form.
The second channel contains spheres with no aptamer. In the second
chamber, therefore, no iron is reduced. Because the oxidation state of
the iron in one chamber has been changed, the two chambers no longer
have the same composition and an electric potential builds up. This can
be measured by means of a capacitor and a measuring device like those
used to test the voltage of a battery.
This principle can be used to easily and inexpensively produce rapid
tests for a broad spectrum of different target molecules.