To prevent terrorist attacks at airports, it would be helpful to detect
extremely low concentrations of explosives easily and reliably. Despite
the development of various sensor technologies, dogs continue to be the
most efficient detectors. In the journal Angewandte Chemie, a German and
French team has now described a type of micromechanical sensor with a
structure derived from the sense organs of butterflies.
One approach used for sensors is based on microcantilevers. These are
tiny flexible cantilevers like those used to scan surfaces with atomic
force microscopes. When used in “chemical noses” the microcantilivers
are coated with a material that specifically binds to the analytes being
detected. Cantilevers can vibrate like springs. When analyte molecules
are bound to a microcantilever, its mass changes along with its
frequency of vibration. This change can be measured.
Because of their very low vapor pressure at room temperature, the highly
sensitive, reliable detection of explosives remains a big challenge. In
order to make microcantilevers more sensitive to the explosive
trinitrotoluene (TNT), research groups led by Denis Spitzer at the
French-German Research Institute of Saint Louis and Valérie Keller at
the Laboratoire des Matériaux, Surfaces et Procédés pour la Catalyse in
Strasbourg have now taken inspiration from the highly sensitive sense
organ of some types of butterfly. Male silk moths use this organ to
recognize pheromone molecules excreted by females as they land on its
broad antennae. These antennae are covered with sensilla, which are
porous hairs containing chemonsensing neurons.
The scientists equipped their microcantilevers like the butterfly
antennae. They coated them with a dense three-dimensionally ordered
layer of titanium dioxide nanotubes oriented vertically, like the
butterfly sensilla. This has several advantages: the specific surface of
the microcantilevers is significantly increased; titanium dioxide binds
well to substances that contain nitro groups, which are characteristic
of TNT and other explosives; also, the tubes have an open structure,
which improves the movement of mass and ensures a rapid sensor response.
The tubes are about 1700 nm long and have an outer diameter of about 100
nm and a wall thickness of 20 nm. Each cantilever holds about 500,000 of
these nanotubes.
For test purposes, the researchers vaporized TNA by heating a tiny
crystal. The sensor was able to detect concentrations of less than one
part per trillion (ppt) within 3 minutes. The researchers are now
working on building a selective detector system for explosives or other
gases based on this method.